powerbreaker electrical supplies
| powerbreaker electrical supplies 1 to 4 of 4 |
|
13a 30ma Double Pole Passive Twin Socket Rcd Electrical Supplies PowerBreaker Slimline, easy to install RCD with neon indicator and power cut-out for added protection. 13A max load, trips 20ms at 30mA. Double pole. Features: Automatic Reset After Power Failure; Fits Standard 25mm Back Box; Twin Earth Terminals. Specifications: 230V AC / 50Hz. Max. 13A (13A inductive). 30mA rated trip current. Typical trip speed 20ms. BS 7288:1990, BS 1363-2:1995, BS EN 61543:1995. Review this product |
![]() Review this store Screwfix |
£30.98 |
Visit Store » |
|
13a 30ma Double Pole Passive Rcd Connection Unit Electrical Supplies PowerBreaker Modern, easy to install RCD connect unit with neon indicator and power cut-out for a13A max load. Trips at 30mA. Fuse holder can be locked out for safety. Double pole. BS 7288:1990, BS 1363-4:1995, BS EN 61543:1995. Passive operation. Features: Automatic Reset After Power Failure; Flush or Surface Mountable. Specifications: 230V AC / 50Hz. Max. 13A (13A inductive). 30mA rated trip current. Typical trip speed 20ms. 6mm max. terminal capacity. BS 7288:1990, BS 1363-4:1995, BS EN 61543:1995. Integral cord outlet and cable clamp. Review this product |
![]() Review this store Screwfix |
£32.54 |
Visit Store » |
|
13a 30ma Double Pole Passive Rcd Metal clad Electrical Supplies PowerBreaker Robust, easy to install RCD with neon indicator and power cut-out for added protection. 13A max load, trips 20ms at 30mA. Double pole. BS 7288:1990, BS 1363-2:1995, BS EN 61543:1995. Passive operation. Features: Automatic Reset After Power Failure; Can be Flush Fitted; Twin Earth Terminals. Specifications: 230V AC / 50Hz. Max. 13A (13A inductive). 30mA rated trip current. Typical trip speed 20ms. BS 7288:1990, BS 1363-2:1995, BS EN 61543:1995. Review this product |
![]() Review this store Screwfix |
£38.46 |
Visit Store » |
|
13a 30ma Passive Rcd Spur Metal clad Electrical Supplies PowerBreaker Robust and easy to install, with neon indicator and power cut-out for added protection. 13A max load. Trips at 30mA. Fuse holder can be locked out for safety. Double pole. BS 7288:1990, BS 1363-4:1995, BS EN 61543:1995. Passive operation. Features: Automatic Reset After Power Failure; Flush or Surface Mountable. Specifications: 230V AC / 50Hz. Max. 13A (13A inductive). 30mA rated trip current. Typical trip speed 20ms. 6mm max. terminal capacity. BS 7288:1990, BS 1363-4:1995, BS EN 61543:1995. Integral cord outlet and cable clamp. Review this product |
![]() Review this store Screwfix |
£47.30 |
Visit Store » |
| powerbreaker electrical supplies 1 to 4 of 4 |











